6.3.1Device Status

Reference Manual

300530EN, Rev BA September 2012

Rosemount 2410

6.3.1Device Status

The current device status is shown in Input Register 1000. You can view the device status register by opening the Diagnostic window (see “Diagnostics” on page 6-7) or the View Input Registers window (see “Viewing Input and Holding Registers” on page 6-2).

Double-clicking the Value field of the Device Status register opens an expanded bitfield window with informaion on the current device status as shown in Figure 6-7.

Figure 6-7. Input Register

Device Status

Double-click the Value field to open the Expanded Bitfield window

Table 6-4. Device status messages

Message

Bit no.

Description

Action

 

 

 

 

Device Warning

1

A device warning is active.

See “Warning Messages” on page 6-24

 

 

 

for details.

 

 

 

 

Device Error

7

A device error is active.

See “Error Messages” on page 6-26for

 

 

 

details.

 

 

 

 

Simulation Mode Active

8

Simulation mode active.

Stop Simulation mode.

 

 

 

 

Write Protected

18

The device is write protected with a switch

Check the write protection switch, see

 

 

or in the TankMaster WinSetup program.

“Write Protection Switch” on page 6-11.

 

 

 

Check write protection state in

 

 

 

TankMaster WinSetup, see “Write

 

 

 

Protection” on page 6-10.

 

 

 

 

Section 6. Service and Troubleshooting