Appendix A

Reference Manual

300530EN, Rev BA September 2012

Rosemount 2410

Appendix A

Reference Data

 

 

 

 

 

 

 

 

 

A.1

Specifications

page A-1

 

A.2

Dimensional drawings

page A-4

 

A.3

Ordering Information

page A-5

A.1 SPECIFICATIONS

 

 

 

 

 

 

 

 

 

 

 

General

 

 

 

 

 

Product

 

Rosemount 2410 Tank Hub

 

 

Single tank version

 

• Supports one 5900S 2-in-1 gauge or two radar level gauges, type 5300, 5400, or 5900S

 

 

• Total Observed Volume (TOV) calculation with 100-point strapping table

Multiple tank version

Examples of connected field devices

Start-up time

Legal custody transfer type approval Hazardous location certifications

Safety/overfill

For a 5300/5400/5900S system configuration:

The software supports 16 field devices and 10 tanks per hub

Maximum five gauges, type 5300 or 5400 per hub

The actual number of tanks/instruments a hub supports depends on the configuration, which types of units are connected and how many. See “Power Budget” on page 3-7.

Hybrid calculations (mass and density) for up to three tanks

Total Observed Volume (TOV) calculation with 100-point strapping table for one tank

Radar Level Gauges (type 5900S(1), 5300, and 5400), Rosemount 2240S Multi-input Temperature Transmitter, Rosemount 644 Temperature Transmitter, Temperature / Water Level Sensors, Rosemount 3051S Scalable Pressure Transmitter, Rosemount 2230 Graphical Display

Less than 30 s

OIML R85:2008, and national certifications such as PTB, NMi etc

ATEX, FM-C, FM-US, IECEx, and national certifications. For details, see “Appendix B: Product Certifications” and “Ordering Information” on page A-5.

SIL 2 and SIL 3 certified.

TÜV tested and WHG approved for overfill prevention. For national approvals, consult your local Rosemount Tank Gauging representative

CE-mark

Complies with applicable EU directives (EMC, ATEX)

Ordinary location certification

Complies with FM 3810:2005 and CSA: C22.2 No. 1010.1

Communication / Display / Configuration

 

Tankbus

The intrinsically safe side of the Rosemount 2410 connects to the Tankbus which

 

communicates with field devices on the tank using FOUNDATION™ fieldbus

Fieldbus

Primary fieldbus: Rosemount 2410 communicates with a host or a field communication unit

 

via TRL2 Modbus, RS485 Modbus, Enraf or HART

 

Secondary fieldbus(2): TRL2 Modbus, Enraf (other options available soon), WirelessHART

 

for Smart Wireless THUM™ Adapter

Relay outputs

SIL safety relay output(3): One SIL 2/SIL 3 certified relay is available for overfill prevention.

 

This non-intrinsically safe solid state relay is closed/energized during normal operation

 

Maximum voltage and current: 260 VAC/VDC, 80 mA

 

Relay outputs (Non-SIL):Maximum two relays, controlled by 10 independent virtual relay

 

functions which can be configured for different tanks and process variables.

 

The two non-intrinsically safe solid state relays are user configurable for normally energized

 

or de-energized operation.

 

Maximum voltage and current: 350 VAC/VDC, 80 mA