6.2.7Device Software Upgrade

Reference Manual

Rosemount 2410

300530EN, Rev BA September 2012

6.2.7Device Software Upgrade

The Rosemount TankMaster WinSetup program allows you to upgrade the 2410 Tank Hub and other Raptor devices with new software.

To upgrade a device with new software do the following:

1.Ensure that the latest versions of *.ini-files are installed on the TankMaster PC. New *.ini files can easily be installed by running the TankMaster setup program located in the DeviceIniFiles folder on the TankMaster installation CD.

2.Ensure that the 2410 Tank Hub communicates with TankMaster without any interruptions or disturbances.

3.In the TankMaster WinSetup workspace window (Logical View) open the Devices folder and select the icon that represents the 2410 Tank Hub to be upgraded (or select the Devices folder to allow multiple devices programming).

4.Click the right mouse button and choose the Program option (Program All option for multiple devices programming).

5.The 2410 will automatically appear in the Program These Devices pane.

6.In case you wish to upgrade several 2410 Tank Hubs simultaneously, you may use the multiple programming options:

a.In the TankMaster WinSetup workspace window select the Devices folder.

b.Click the right mouse button and choose the Program All option to open the Program Devices window:

6-8

Section 6. Service and Troubleshooting

Page 82