Source Configuration tab.)

Reference Manual

300530EN, Rev BA September 2012

Rosemount 2410

Message

Description

Action

 

 

 

Map conflict tank no.

Input register no. 6260

 

Map conflict TMV type

Input register no. 6262

 

(TMV=Tank Measurement Variable)

0: TMV Level

 

 

1: TMV Ullage

 

 

2: TMV Level Rate

 

 

3: TMV Signal Strength

 

 

4: TMV Free Water Level

 

 

5: TMV Vapor Pressure

 

 

6: TMV Liquid Pressure

 

 

7: TMV Air Pressure

 

 

8: TMV Ambient Temperature

 

 

9: TMV Vapor Avg Temperature

 

 

10: TMV Liquid Avg Temperature

 

 

11: TMV Tank Avg Temperature

 

 

12-27: TMV Temp1 - TMV Temp 16

Check that tank measurement variables

 

50: TMV Observed Density

 

51: TMV Reference Density

are mapped to the right source

 

52: TMV Flow Rate

parameters (In TankMaster Winsetup,

 

53: TMV Tank Volume

right-click the ATD device icon associated

 

54: TMV Tank Height

with the current tank, and click the

 

55: TMV Middle Pressure

Properties option. In the 22XX ATD

 

56: TMV Delta Level

window select the Advanced Parameter

 

60-64: TMV USER DEF 1 - 5

Source Configuration tab.)

Map conflict device 1

Input register no. 6264

Contact Emerson Process

Map conflict device 1 TV no.

Input register no. 6266

Management/Rosemount TankGauging

(TV=Tank Variable)

TV number 0 - 1019 (Level, Ullage, Level

service department.

 

Rate, Signal Strength etc.)

 

 

Map conflict device 2

Input register no. 6268

 

Map conflict device 2 TV no.

Input register no. 6270

 

(TV=Tank Variable)

TV number 0 - 1019 (Level, Ullage, Level

 

 

Rate, Signal Strength etc.)

 

Internal map conflict

Input register no. 6272

 

 

Bit 1: TMV Vapor average temperature

 

 

Bit 2: TMV Liquid average temperature

 

 

Bit 3: TMV Tank average temperature

 

 

Bit 4: TMV Observed Density

 

 

Bit 5: TMV Reference Density

 

 

Bit 6: TMV Tank Volume

 

 

Bit 7: Mult TV Map

 

 

Bit 8: TMV Internal Map

 

 

Bit 9: TMV Arithmetic Value

 

Section 6. Service and Troubleshooting

6-25

Page 99
Image 99