Fujitsu N800 manual Fans, System expansions

Models: N800

1 142
Download 142 pages 2.29 Kb
Page 104
Image 104
Fans

Fans

System expansions

 

2

 

1

Figure 23: Removing a power supply unit

ÊPull the power supply unit handle down (1) to unlock it from the chassis.

ÊPull the power supply unit in the direction of the arrow, out of the bay. Mounting is performed in reverse order.

8.4Fans

The system is equipped with six fans. The fans are mounted in the fan array housing placed at the front side of the server and covered by the front bezel.

The fan status can be displayed via the server management software ServerView. Additionally, when a fan fails, the yellow fan failure LED on the front panel will be on continuously. Which fan is defective can be determined by checking each yellow LED mounted next to each fan (under the fan housing cover).

IEven though the server can continue operating with only five fans, the defective fan must be replaced in a reasonable amount of time.

Due to the hot-plug architecture, replacement can also take place during operation.