CMOS Clear:

Configuring the server and components Preparation for use and operation

CMOS Clear:

This switch controls whether settings stored in non-volatile CMOS memory (NVRAM) are retained when the system is reset or whether the default settings are loaded.

If you want to change the settings in NVRAM, proceed as follows:

ÊFollow the procedure described in the section “Changing the switch settings” on page 39.

ÊSet DIP switch 2 (see table 2 on page 38) to ON.

ÊSwitch the system on. Wait for POST to complete and for the following messages to be displayed on the screen:

lup[k

nr

This reprograms CMOS and RTC to the default settings, except for the password.

ÊPress [ to start BIOS Setup and make any necessary changes. Press to save the new settings and exit Setup.

ÊShut down the system, turn the server off and disconnect it from the line voltage.

ÊReset DIP switch 2 (see table 2 on page 38) to OFF.

ÊReconnect all peripheral devices, reconnect the server to the line voltage, and switch the server on.

ÊRun BIOS Setup to save the desired settings (see section “BIOS Setup” on page 47).