1.6Technical data
Electrical data
Rated voltage range | 100 V - 120 V |
| 200 V - 240 V (auto sense) |
|
|
Rated voltage tolerance | +6 % / |
|
|
Frequency | 50 Hz / 60 Hz |
|
|
Rated current at 100V - 120 V | 12 A |
|
|
Rated current at 200V - 240 V | 7 A |
|
|
Effective power | 1247 W |
|
|
Apparent power | 1271 VA |
|
|
Heat emission | 4014 kJh |
|
|
Building fuse | 16 A |
|
|
Protection class | I |
|
|
|
|
Dimensions and weight |
|
|
|
Height (mm) | 312 (seven height units) |
|
|
Width (mm) | 445 |
|
|
Depth (mm) | 712 |
|
|
Weight (kg) | max. 60 (maximum configuration) |
|
|
Environmental conditions (according to DIN EN 60721-3-x)
Operating climate (Class 3K2):
Temperature (°C) | 10 to 35 |
|
|
Relative humidity(%) | 5 to 85 |
|
|
Environmental conditions/transport (Class 2K2):
Temperature (°C) | |
|
|
Relative humidity (%) | 15 to 98 |
|
|
Mechanical environmental conditions |
|
|
|
Operation | Class 3M2 |
|
|
Transport | Class 2M2 |
|
|