Mounting the server in the rack

Mounting the server in the rack

Installing the server

3.2Mounting the server in the rack

VCAUTION!

Please take note of the safety information and the notes on mounting in the rack in the chapter “Important notes” on page 11.

At least two people are needed to position the server in the rack.

The rack may tip over if more than one heavy unit is removed.

Mounting the installation kit and the server

For mounting the server in the DataCenter Rack at first a support bracket must be mounted on the rear left support upright. The support bracket must be mounted level with the lower edge of the server. Cage nuts and/or spring nuts also must be inserted in the support uprights. The support bracket is used for the rear fixing of the left carrier rail, the cage nuts are used for fixing the support bracket and the front panel, the spring nuts for fixing the carrier rails:

ÊTake the fitting instruction in the Technical Manual for the corresponding rack model for aid.

ÊUsing the mounting aid (stencil) mark the position of the attachment points of the server on the support uprights (7 height units).

Refer to the information on the mounting aid.

ÊMount the support bracket using two screws and cage nuts on the corre- sponding height on the rear left support upright.

ÊIf required, you can mount one additional a cable clip for vertical cable routing.

ÊMark the mounting points of the server (knurled screws on the front panel) on the front support upright. Also mark the fastening points of the telescopic rails on the inside grooves of the support uprights facing backwards. The bottom edge of the fastening flange must be flush with the top housing cover of any device already mounted.

ÊPlace the cage nuts and/or the spring nuts in the groove of the support uprights and/or of the support bracket at the marked attachment points. If necessary, adjust the position of the nuts in the groove until they lock into the correct position.