Chapter 15. Command Line Reference
misc.unitname
Corresponding setting in web GUI: Name of this Telecommuting Module on page Basic Configuration
Table type: Single row
The name of this Ingate unit.
Field Name | Field Type | Explanation |
unitname | OptString | The |
misc.use_ntp
Corresponding setting in web GUI: Change Date and Time With NTP on page Date and Time
Table type: Single row
Activate NTP for the Ingate system clock.
Field Name | Field Type | Explanation |
enabled | OnOffToggle | Turns the setting on or off. |
monitor.cpuload_level_alarm
Corresponding setting in web GUI: CPU Load Trap Levels on page SNMP
Table type: Single row
When to create alarm messages for high CPU load.
Field Name | Field Type | Explanation |
max_cpuload | OptPercent | The load level when an alarm message |
|
| should be created and the alarm state set. |
ok_cpuload | OptPercent | The load level when the alarm state is reset. |
monitor.email_alert_logclass
Corresponding setting in web GUI: Log class for email errors on page Logging Configura- tion
Table type: Single row
The log class for email errors.
Field Name | Field Type | Explanation |
logclass | LogclassReference | A log class. |
monitor.email_server
Corresponding setting in web GUI: SMTP Server on page Log Sending
Table type: Single row
The SMTP server to use when log messages are sent to an email address.
255