HUAWEI MC509 CDMA LGA Module

 

AT Command Interface Specification

Basic Configuration Commands

2.3.2Interface Description

This command sets the response format character S4. S4 saves the response format character in the ASCII code format. The character is sent by the MT to compose the headers, tails, and end flags of the result code and response information.

If the S4 character is changed by the command, the new S4 will be immediately returned with the result code of the command.

2.3.3Parameter Description

<value>: A decimal number ranges from 000 to 127, indicating the ASCII code of the character. The default value is 010.

ATS4=1 is equivalent to ATS4=001.

2.4 S5Backspace Character

2.4.1 Syntax

Command

Possible Response(s)

 

 

S5=<value>

<CR><LF>OK<CR><LF>

 

 

S5?

<CR><LF><value><CR><LF>

 

<CR><LF>OK<CR><LF>

 

 

2.4.2Interface Description

This command sets the backspace character S5. S5 saves the backspace character in the ASCII code format. The character is sent by the TE as a request to delete the previous character and is identified and confirmed by the MT.

2.4.3Parameter Description

<value>: A decimal number ranges from 000 to 127, indicating the ASCII code of the character. The default value is 008.

ATS5=1 is equivalent to ATS5=001.

Issue 01 (2011-08-26)