HUAWEI MC509 CDMA LGA Module

 

AT Command Interface Specification

Call Control Commands

7.14.2Interface Description

This command sets the Point to Point Protocol (PPP) user name and password before data service dial-up. After the dial-up connection is successful, the client can use the user name and password to establish a PPP connection.

7.14.3Parameter Description

<userid>: Specifies the PPP authentication user name. It is a string with double quotation marks. The maximum length is 127 characters excluding the double quotation marks.

<password>: Specifies the PPP authentication password. It is a string with double quotation marks. The maximum length is 127 characters excluding the double quotation marks.

7.14.4Example

AT^PPPCFG="Huawei","Huawei"

OK

7.15 +CTACommand for Setting operating mode

7.15.1 Syntax

 

Command

 

Possible Response(s)

 

 

 

 

 

+CTA=<cta>

 

<CR><LF>OK<CR><LF>

 

 

 

In case of an MT-related error:

 

 

 

<CR><LF>ERROR:<err><CR><LF>

 

 

 

 

 

+CTA?

 

<CR><LF>+CTA:<n><CR><LF>

 

 

 

In case of an MT-related error:

 

 

 

<CR><LF>ERROR:<err><CR><LF>

 

 

 

 

 

+CTA=?

 

<CR><LF>+CTA:(supported <n> list)<CR><LF>

 

 

 

 

 

 

In case of an MT-related error:

 

 

 

<CR><LF>ERROR:<err><CR><LF>

 

 

 

 

7.15.2Interface Description

Execution command use to set the time to enter the dormant.

Read command use to read the time to enter the dormant.

Test command use to test the time to enter the dormant.

Issue 01 (2011-08-26)

Huawei Proprietary and Confidential

82

Copyright © Huawei Technologies Co., Ltd.

 

 

Page 82
Image 82
Huawei MC509 manual 15 +CTA-Command for Setting operating mode, +Cta?