HUAWEI MC509 CDMA LGA Module

 

AT Command Interface Specification

Security Control Commands

0:unlocking

1:locking

2:status query <status>:

0:deactivated

1:activated

<passwd>: A string with double quotation marks. It should be the same as the password set by running the +CPWD command. This item is mandatory when mode is set to 0 or 1. The parameter value must be a string consisting of digits 0–9. Otherwise, "ERROR" is returned.

<class>: Reserved and not supported at present

4.2 +CPINPIN Management Command

4.2.1 Syntax

Command

Possible Response(s)

 

 

+CPIN=<pin>[,<newpin>]

<CR><LF>OK<CR><LF>

 

In case of an MT-related error:

 

<CR><LF>+CME ERROR:<err><CR><LF>

 

 

+CPIN?

<CR><LF>+CPIN:<code><CR><LF>

 

<CR><LF>OK<CR><LF>

 

 

+CPIN=?

<CR><LF>OK<CR><LF>

 

 

4.2.2Interface Description

The execution command verifies and unlocks the PIN and PIN2 codes.

If PIN or PIN2 is requested, run +CPIN=<pin> for verification.

If PUK or PUK2 is requested, run +CPIN=<pin>,<newpin> for unlocking. The first parameter is R-UIM PUK or R-UIM PUK2. The second parameter is the new PIN or PIN2 code.

If the PIN is not requested and the execution command is run, the error information +CME ERROR is returned.

Issue 01 (2011-08-26)

Huawei Proprietary and Confidential

47

Copyright © Huawei Technologies Co., Ltd.

 

 