HUAWEI MC509 CDMA LGA Module

 

AT Command Interface Specification

Serial Port Control Commands

Automatic detection of the baud rate is not supported at present. Therefore, the first returned parameter list is blank when the test command is executed. For example: +IPR:(),(300,600,1200,2400,4800,9600,19200,38400,57600,115200,230400)

If the physical serial port baud rate is higher than the radio bearer rate, data may be lost when being transmitted.

After the baud rate is changed, wait for a period of time (for example, 100 ms) before continuing the communication.

5.5.3Parameter Description

<rate>: Specifies the baud rate. It is a decimal integer. The values are as follows: 300,600,1200,2400,4800,9600,19200,38400,57600,115200,230400

AT+IPR without a parameter is equivalent to AT+IPR=115200.

5.6 +IFCCommand for Setting Flow Control

5.6.1 Syntax

Command

Possible Response(s)

 

 

+IFC[=<DCE_by_DTE>

<CR><LF>OK<CR><LF>

[,<DTE_by_DCE>]]

In case of an MT-related error:

 

<CR><LF>ERROR<CR><LF>

 

 

+IFC?

<CR><LF>+IFC:<DCE_by_DTE>,<DTE_by_DCE><

 

CR><LF>

 

<CR><LF>OK<CR><LF>

 

 

+IFC=?

<CR><LF>+IFC:(supported <DCE_by_DTE> list),

 

(supported <DTE_by_DCE> list)<CR><LF>

 

<CR><LF>OK<CR><LF>

 

 

5.6.2Interface Description

This command sets and queries bidirectional flow control.

5.6.3Parameter Description

<DCE_by_DTE>:

0: none (default value after startup)