Huawei MC509 manual MSO-Shutdown Command, HS-Command for Shaking Hands with the TE, MSO Crlfokcrlf

Models: MC509

1 156
Download 156 pages 43.92 Kb
Page 35
Image 35

HUAWEI MC509 CDMA LGA Module

 

AT Command Interface Specification

Basic Configuration Commands

2.13.3Parameter Description

<delay_time>: Delay time.

0

Disable the function of this command.

1~65535 Delay time, indicates in second.

AT^RESET without a parameter is equivalent to AT^RESET=0.

2.14 ^MSOShutdown Command

2.14.1 Syntax

Command

Possible Response(s)

 

 

^MSO

<CR><LF>OK<CR><LF>

 

 

2.14.2Interface Description

This command powers off the MT. When the command is executed, the MT logs out of the network, saves subscriber data, and then shut down.

2.15 ^HSCommand for Shaking Hands with the TE

2.15.1 Syntax

Command

Possible Response(s)

 

 

^HS=<id>,<action>

<CR><LF>^HS:<id>,<protocol>,<is_offline>,<produ

 

ct_class>,<product_id>[,<software_id>]

 

<CR><LF><CR><LF>OK<CR><LF>

 

 

2.15.2Interface Description

This command initiates a handshake between the TE and the MT.

2.15.3Parameter Description

<id>: Consists of eight hex digits. It indicates the ID reported by the MT for identifying the MT. When the TE sends this command for the first time, id is set to 0, and then id is set to the value reported by the MT.

Issue 01 (2011-08-26)

Huawei Proprietary and Confidential

35

Copyright © Huawei Technologies Co., Ltd.

 

 