Explanation: An error occurred when the workflow received as the input parameter a software resource ID that does not contain a valid software module ID. A valid software module ID is required to identify which package will be uninstalled from the specified system.

Operator response: Verify that the provided software resource references the correct software module. Verify that the package was installed on the specified system using a workflow that implements SoftwareInstallable.Install.

Explanation: No additional information is available for this message.

COPCOM007E The software resource with ID VALUE_0 does not have a valid server

ID.

Explanation: An error occurred when the workflow received as the input parameter a software resource ID that does not contain a valid server ID. A valid server ID is required to identify the target system.

Operator response: Verify that the package was installed on the specified system using a workflow that implements SoftwareInstallable.Install.

COPCOM008E The system cannot open a Telnet connection to "VALUE_0".

Explanation: The user setting might be incorrect.

Operator response: From the command line, try to create the Telnet connection as ’userid’.

COPCOM009E The variable TMA.Label_propkey is undefined in the server with ID VALUE_0.

Explanation: An error occurred when the variable TMA.Label_propkey was not defined on the server. This property is needed since it identifies the IBM Tivoli Management Agent in systems that have more than one agent. The value of this property is the name of a second property. The second property contains the name of the IBM Tivoli Managed Agent label.

Administrator Response: Verify that the server has a variable named TMA.Label_propkey in the DEPLOYMENT_ENGINE scope.

Explanation: No additional information is available for this message.

COPCOM010E The third party software package with ID VALUE_0 does not have the required file name and file path.

Explanation: An error occurred during the registration of the Software Package Block when the third party software package did not have specify the name and path of the Software Package Block.

Operator response: Verify that registration was performed on the correct third party software package.

Administrator Response: Verify that the third party software package was defined using the correct file name and path attributes.

Explanation: No additional information is available for this message.

COPCOM011E The discovery object VALUE_0 does not have a valid filter string.

Explanation: The provided discovery object does not have the required property tcm.software.filter, tcm.hardware.pm.filter. Those properties are used to define which IBM Tivoli Configuration Manager resources will be imported into IBM . The defined filter value should be in the format:

PR=PolicyRegionValue;PM=ProfileManagerValue;

SP=SoftwarePackageValue;I=True.

Operator response: Verify that the correct discovery object was used. Verify that the discovery object has the required filter string properties.

Explanation: No additional information is available for this message.

COPCOM012E The server VALUE_0 does not have a locale value.

Explanation: An error occurred in the workflow because the server specified has a locale value that is null. The locale value is required to specify the locale value of the items that will be imported into the IBM database.

Administrator Response: Verify that the server object does not have null locale value.

COPCOM013E The system cannot find the NIC for network interface IP "VALUE_0".

Explanation: This is a validation issue.

Operator response: Validate the NIC information.

COPCOM014E The system cannot find the software

stack with ID: "VALUE_0".

Explanation: This is a validation issue.

Operator response: Validate the software stack information.

COPCOM015E The system cannot get a JNDI context.

Explanation: No additional information is available for this message.