Health Events

11.4.2

CMM Location

 

 

 

 

 

Table 39. CMM Redundancy

 

 

 

 

 

 

 

 

 

 

 

 

Event String

Event Code

Event Severity

 

Hex

 

Decimal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

"Regained"

0x0D0

 

208

OK

 

 

 

 

 

 

 

 

"Established"

0x0D1

 

209

OK

 

 

 

 

 

 

 

 

"Lost due to switch failure"

0x0D2

 

210

Major

 

 

 

 

 

 

 

 

"Lost due to unhealthy signal"

0x0D3

 

211

Major

 

 

 

 

 

 

 

 

"Lost due to CMM removal"

0x0D5

 

213

Major

 

 

 

 

 

 

 

 

"Lost due to CMM reboot or halt"

0x0D6

 

214

Major

 

 

 

 

 

 

 

 

"Lost due to critical event on the CMM"

0x0D7

 

215

Major

 

 

 

 

 

 

 

 

"Lost due to inability to communicate with the other CMM over its

0x0D8

 

216

Major

 

management bus."

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

"Lost due to incompatible firmware versions on the CMMs.

0x0EF

 

239

Major

 

Please upgrade the CMMs to the same version."

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 40. CMM Trap Connectivity (CMM [1-2] Trap Conn)

 

 

 

 

 

 

 

 

 

 

 

Event String

Event Code

Event Severity

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

“Regained”

0x0D0

 

208

OK

 

 

 

 

 

 

 

 

"Lost due to failed network connectivity between the CMM and

0x0D4

 

212

Major

 

the Primary SNMP trap destination (SNMPTrapAddress1)."

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 41. CMM Failover (Sheet 1 of 2)

 

 

 

 

 

 

 

 

 

 

 

Event String

Event Code

Event Severity

 

Hex

 

 

Decimal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

“Failover occurred."

0x0D9

 

217

OK

 

 

 

 

 

 

 

“Failover occurred because of switch failure.”

0x0DA

 

218

OK

 

 

 

 

 

 

 

 

“Failover occurred because of failed network connectivity

0x0DB

 

219

OK

 

between the CMM and the Primary SNMP trap destination.”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

“Failover occurred because of critical CMM health events.”

0x0DC

 

220

OK

 

 

 

 

 

 

 

 

“Failover occurred because of a bad hardware signal from the

0x0DD

 

221

OK

 

other CMM.”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

“Failover occurred because it was forced by the user.”

0x0DE

 

222

OK

 

 

 

 

 

 

 

 

“Failover cannot occur because the other CMM has a bad

0x0E0

 

224

OK

 

switch.”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

“Failover cannot occur because the other CMM has lost network

0x0E1

 

225

OK

 

connectivity with its Primary SNMP trap destination.”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

“Failover cannot occur because the other CMM has critical

0x0E2

 

226

OK

 

health events.”

 

 

 

 

 

 

 

 

 

 

 

 

 

 