SNMP

Table 61. Shelf Location (Equivalent to Chassis) (1.3.6.1.4.1.343.2.14.2.10.2)

OID

Object

Syntax

Access

Value

 

 

 

 

 

 

 

 

 

Used to find out what targets are

1

shelfListTargets

DisplayString

read-only

available on a location. (e.g., Getting

 

 

 

 

the list of sensors in the chassis).

 

 

 

 

 

2

shelfListDataItems

DisplayString

read-only

Used to find out what data items are

available on a target or location.

 

 

 

 

 

 

 

 

 

 

 

 

 

Used to get or set the fan speed in the

 

 

 

 

chassis. Percent of the maximum fan

3

shelfFanSpeed

DisplayString

read-write

speed that the chassis supports. Values

 

 

 

 

can be multiples of 10 from 20 to 100,

 

 

 

 

or 0xFE for emergency shutdown.

 

 

 

 

 

 

 

 

 

This is used to get or set the Location

4

shelfLocation

DisplayString

read-write

field in the chassis FRU and is sent out

as a part of SNMP and UDP alerts. This

 

 

 

 

is only used with the chassis location.

 

 

 

 

 

 

 

 

 

Health information about a particular

5

shelfHealth

INTEGER

read-only

Location. This will be one of the

following: (0-OK, 1-Minor, 2-Major, 3-

 

 

 

 

 

 

 

 

Critical).

 

 

 

 

 

 

 

 

 

Events that contribute to the Health of

6

shelfHealthEvents

DisplayString

read-only

the Location. This is a list of events

 

 

 

 

happening on the Location.

 

 

 

 

 

7

shelfIPMICommandRequest

DisplayString

read-write

Used to send any IPMI command to

this location.

 

 

 

 

 

8

shelfIPMICommandResponse

DisplayString

read-only

Used to read the response to the above

IPMI command.

 

 

 

 

 

 

 

 

 

1

Table 62. ShelfTable/shelfEntry (1.3.6.1.4.1.343.2.14.2.10.2.50.1) (Sheet 1 of 2)

OID

Object

Syntax

Access

Value

 

 

 

 

 

1

shelfTarget

OCTET

none

index

STRING

 

 

 

 

 

 

 

 

 

23

shelfMinorAction

DisplayString

write-only

Used to configure user defined actions

when minor events occur.

 

 

 

 

 

 

 

 

 

24

shelfMajorAction

DisplayString

write-only

Used to configure user defined actions

when major events occur.

 

 

 

 

 

 

 

 

 

25

shelfCriticalAction

OCTET

write-only

Used to configure user defined actions

STRING

when critical events occur.

 

 

 

 

 

 

 

 

26

shelfNormalAction

OCTET

write-only

Used to configure user defined actions

STRING

when normal events occur.

 

 

 

 

 

 

 

 

27

shelffruBoardDescription

DisplayString

read-only

Used to read the Board Description

from the FRU.

 

 

 

 

 

 

 

 

 

28

shelffruBoardManufacturer

DisplayString

read-only

Used to read the Board Manufacturer

from the FRU.

 

 

 

 

 

 

 

 

 

29

shelffruBoardPartNumber

DisplayString

read-only

Used to read the Board Part Number

from the FRU.

 

 

 

 

 

 

 

 

 

30

shelffruBoardSerialNumber

DisplayString

read-only

Used to read the Board Serial Number

from the FRU.

 

 

 

 

 

 

 

 

 

144MPCMM0001 Chassis Management Module Software Technical Product Specification

Page 144
Image 144
Intel MPCMM0001 manual Shelf Location Equivalent to Chassis, String