The Command Line Interface (CLI)

Table 27. Dataitem Keywords for Cmm Location (Sheet 5 of 7)

dataitem

Description

Get/

CLI Get Output

Valid Set Values

Set

 

 

 

 

 

 

 

 

 

 

Gets/Sets whether the LED

 

 

 

syncuserledstate

state is synced between the

Both

"Yes" or "No"

“Yes” or “No”

 

active and standby CMM.

 

 

 

 

 

 

 

 

 

 

 

It will be in INI format displayed on the

 

 

 

 

console as follows:

 

 

 

 

[Settings]

 

 

Used to get/set the power

 

EntryCount=xxx

 

 

sequence order, Power

 

 

 

 

Sequencing Delay,

 

[Power Sequence 1]

 

 

ShelfManagerControlledActiva

 

 

 

 

Location=cmm1

 

 

tion in the CDM.

 

 

 

 

FRUDeviceID=0

 

 

Note: The power sequencing

 

 

 

delay is in tenths of a second

 

ShelfManagerControlledActivation=Ye

INI file with its path,

 

to delay before powering up

Both

s

powersequence

any other FRU after powering

DelayBeforeNextPowerOn=0

such as "-v /home/

 

this FRU. The value of the

 

PowerSeq.INI"

 

 

 

 

power sequencing delay is

 

 

 

 

between 0 and 63. Shelf

 

[Power Sequence 2]

 

 

Manager Controlled Activation

 

… …

 

 

determines if the Shelf

 

 

 

 

 

 

 

Manager activates the FRU

 

 

 

 

residing at this location when it

 

[Power Sequence xxx]

 

 

reaches M2.

 

Location=blade12

 

 

 

 

 

 

 

 

FRUDeviceID=0

 

 

 

 

ShelfManagerControlledActivation=N

 

 

 

 

o

 

 

 

 

DelayBeforeNextPowerOn=0

 

 

 

 

 

 

 

 

 

 

"OEMWelcomeMes

 

 

 

 

sage" where the

 

Used to customize the login

 

 

OEMWelcomeMess

 

 

The OEM string that is displayed at

age is the message

loginmessage

screen message by allowing

Both

the login screen

that will appear at

 

user to add the OEM name.

 

 

 

 

the login screen

 

 

 

 

 

 

 

 

Max length = 63

 

 

 

 

characters

 

 

 

 

 

 

 

 

 

"OEMName" where

 

 

 

 

the OEMName is

 

Used to customize the bash

 

 

the string that will

 

 

The OEM Name string to be

appear at the

cmdlineprompt

prompt by allowing user to add

Both

prepended to the $PS1 variable

beginning of the

 

the OEM name.

 

 

 

 

bash prompt.

 

 

 

 

 

 

 

 

Max length = 63

 

 

 

 

characters

 

 

 

 

 

 

Get/Set the color of the fault/

 

 

 

 

health LED on the CMM

 

 

 

FaultLEDColor

fronted FRUs (Filter Tray,

Both

"amber" or "red"

“amber” or “red”

CDM) to be used when an

 

 

 

 

 

error is reported. Does not

 

 

 

 

affect CMM Health LED.

 

 

 

 

 

 

 

 

90MPCMM0001 Chassis Management Module Software Technical Product Specification

Page 90
Image 90
Intel MPCMM0001 manual Dataitem Keywords for Cmm Location Sheet 5