Intel MPCMM0001 manual Dataitem Keywords for Chassis Location, MPCHC0001

Models: MPCMM0001

1 281
Download 281 pages 15.26 Kb
Page 85
Image 85

The Command Line Interface (CLI)

Table 26. Dataitem Keywords for Chassis Location

dataitem

Description

Get/Set

CLI Get Output

Valid Set Values

 

 

 

 

 

 

 

 

 

A numerical value

 

Used to get or set the fan

 

 

between 0 and 100

 

 

 

(i.e., “70”),

 

speed of all fans in the

 

 

 

 

The percentage of the max speed,

“localcontrol”, or

 

chassis. Value is percent of

 

 

Both

"Emergency Shut Down", or "Local

“emergencyshutdow

fanspeed

the maximum fan speed. See

Control". For example, 80 for 80% of

n”

 

Section 16, “Fan Control and

 

 

 

the max speed.

(localcontrol is not

 

Monitoring” on page 132 for

 

 

 

 

supported on the

 

more information.

 

 

 

 

 

MPCHC0001

 

 

 

 

 

 

 

 

chassis fan tray.)

 

 

 

 

 

 

This is used to get or set the

 

"Shelf Address: <address>"

 

 

Location field in the chassis

 

Where:

Location String less

 

FRU and is sent out as a part

 

<address> is a space-separated list

location

Both

than 16 characters

of SNMP and UDP alarts. This

 

 

of two-digit, hex numbers if the

in length.

 

is only used with the chassis

 

 

 

address’ type/len byte is 0, decoded

 

 

location.

 

 

 

 

string otherwise

 

 

 

 

 

 

 

 

 

 

MPCMM0001 Chassis Management Module Software Technical Product Specification

85

Page 85
Image 85
Intel MPCMM0001 manual Dataitem Keywords for Chassis Location, MPCHC0001