Intel MPCMM0001 manual FanTrayMaximumSetting

Models: MPCMM0001

1 281
Download 281 pages 15.26 Kb
Page 156
Image 156

SNMP

Table 72. [FanTray/pem]Table/[fanTray/pem]Entry (1.3.6.1.4.1.343.2.14.2.10.[5/6].51.1)

OID

Object

Syntax

Access

Value

 

 

 

 

 

19

fanTrayMaximumSetting

DisplayString

read-only

The fantray's maximum setting.

 

 

 

 

 

20

fanTrayRecommendedSetting

DisplayString

read-only

The fantray's recommended setting.

 

 

 

 

 

21

fanTrayCurrentFanLevel

DisplayString

read-only

The fantray's current fan level.

 

 

 

 

 

Table 73. [FanTray/pem]TargetTable/[fanTray/pem]TargetEntry (1.3.6.1.4.1.343.2.14.2.10.[5/ 6].52.1) (Sheet 1 of 2)

OID

Object

Syntax

Access

Value

 

 

 

 

 

1

[fanTray/pem]Number

INTEGER

none

Index 1

 

 

 

 

 

2

[fanTray/pem]Target

DisplayString

none

Index 2

 

 

 

 

 

3

[fanTray/pem]Current

DisplayString

read-only

The current value of a sensor.

 

 

 

 

 

4

[fanTray/pem]ThresholdsAll

DisplayString

read-only

All thresholds of a sensor.

 

 

 

 

 

5

[fanTray/pem]UpperCritical

DisplayString

read-only

Upper critical thresholds

 

 

 

 

 

6

[fanTray/pem]UpperNonCritical

DisplayString

read-only

Upper non-critical thresholds

 

 

 

 

 

7

[fanTray/pem]LowerNonCritical

DisplayString

read-only

Lower non-critical thresholds

 

 

 

 

 

8

[fanTray/pem]LowerCritical

DisplayString

read-only

Lower critical thresholds

 

 

 

 

 

9

[fanTray/

DisplayString

read-only

Upper non recoverable thresholds

pem]UpperNonRecoverable

 

 

 

 

 

 

 

 

 

10

[fanTray/

DisplayString

read-only

Lower non recoverable thresholds

pem]LowerNonRecoverable

 

 

 

 

 

 

 

 

 

 

 

 

 

Health information about a particular

14

[fanTray/pem]SensorHealth

INTEGER

read-only

location/sensor. This will be one of

the following: (0-OK, 1-Minor, 2-

 

 

 

 

 

 

 

 

Major, 3-Critical).

 

 

 

 

 

 

[fanTray/

 

 

Events that contribute to the health

15

DisplayString

read-only

of the location/sensor. This is a list of

pem]SensorHealthEvents

 

 

 

events happening on the location.

 

 

 

 

 

 

 

 

 

16

[fanTray/pem]MinorAction

OCTET

read-write

Used to configure user defined

STRING

actions when minor events occur.

 

 

 

 

 

17

[fanTray/pem]MajorAction

OCTET

read-write

Used to configure user defined

STRING

actions when major events occur.

 

 

 

 

 

18

[fanTray/pem]CriticalAction

OCTET

read-write

Used to configure user defined

STRING

actions when critical events occur.

 

 

 

 

 

19

[fanTray/pem]NormalAction

OCTET

read-write

Used to configure user defined

STRING

actions when normal events occur.

 

 

 

 

 

20

[fanTray/

DisplayString

read-only

Used to read the Board Description

pem]fruBoardDescription

from the FRU.

 

 

 

 

 

 

 

 

21

[fanTray/

DisplayString

read-only

Used to read the Board

pem]fruBoardManufacturer

Manufacturer from the FRU.

 

 

 

 

 

 

 

 

22

[fanTray/

DisplayString

read-only

Used to read the Board Part Number

pem]fruBoardPartNumber

from the FRU.

 

 

 

 

 

 

 

 

23

[fanTray/

DisplayString

read-only

Used to read the Board Serial

pem]fruBoardSerialNumber

Number from the FRU.

 

 

 

 

 

 

 

 

24

[fanTray/

DisplayString

read-only

Used to read the Board Manufacture

pem]fruBoardManufactureDate

Date from the FRU.

 

 

 

 

 

 

 

 

156MPCMM0001 Chassis Management Module Software Technical Product Specification