Redundancy, Synchronization, and Failover

Priority 2 data is synced.

Data Synchronization has encountered a problem in synchronizing data.

Data Sync becomes normal after Data Sync failure

The current value is 0x000f

Initial Data Synchronization is complete.

Priority 1 data is synced.

Priority 2 data is synced.

No Data Synchronization problems known

Single CMM

The current value is 0x0000

Datasync disabled - there is no partner CMM present.

3.5.4SEL Event

The Datasync Status sensor generates the following two SEL events:

When the active CMM is or becomes the only CMM, or the active CMM loses communication with the standby CMM, the following event will be logged:

[Day] [Month] [Date]

[Time] [Year]

 

CMM[n]: CMM Datasync Status

Initial Data Synchronization is

complete. Deasserted

 

 

The following event will be logged in the SEL when initial data synchronization is complete:

[Day] [Month] [Date] [Time] [Year]

 

CMM[n]: CMM Datasync Status

Initial Data Synchronization is

complete. Asserted

 

Where

n: The number of the CMM generating the event.

3.5.5SNMP Trap

The Datasync Status sensor generates following two SNMP traps:

When the active CMM is or becomes the only CMM, or the active CMM loses communication with the standby CMM, the following SNMP trap will be generated.

[Month] [Date] [Time] [hostname] snmptrapd[xxxxx]: [IP Address]:

Enterprise Specific Trap (25) Uptime: [Time], SNMPv2-

SMI::enterprises.343.2.14.1.5 = STRING: "Time : [Day] [Month] [Date]

[Time] [Year], Location : [location] , Chassis Serial # : [xxxxxxxx],

Board : CMM[x] , Sensor : Datasync Status , Event : Initial Data

Synchronization complete: Deasserted "

MPCMM0001 Chassis Management Module Software Technical Product Specification

27

Page 27
Image 27
Intel MPCMM0001 manual SEL Event, Snmp Trap