The Command Line Interface (CLI)

Table 27. Dataitem Keywords for Cmm Location (Sheet 7 of 7)

dataitem

Description

Get/

CLI Get Output

Valid Set Values

Set

 

 

 

 

 

 

 

 

 

 

Used to request to reboot the

 

 

1 - Request to

standbycmmreboot

standby CMM from the active

Set

N/A

reboot the standby

 

CMM.

 

 

CMM

 

 

 

 

 

 

Get the power feed count for

 

 

 

 

that location. Determines

 

 

 

feedcount

number of feed targets (i.e.,

Get

Integer number

N/A

feed1) for that location. See

 

 

 

 

 

Section 7.7, “Power Feed

 

 

 

 

Targets” on page 69.

 

 

 

 

 

 

 

 

failoveronredundancy

Used to set the failover

Both

automatic, manual

automatic, manual

configuration flag

 

 

 

 

 

 

 

 

 

 

Used to set the direction of

 

 

upgrade,

 

synchronization for home

 

“upgrade”, “downgrade”, “always”,

syncuserscripts

Both

downgrade, always,

scripts when the CMM

“equal”

 

 

equal

 

versions differ.

 

 

 

 

 

 

 

 

 

 

 

 

Uset to get/set SNMP trap

 

“1” - text

“1” - text

snmptrapformat

Both

“2” -raw

“2” - raw

format

 

 

“3”-text+raw

“3” - text+raw

 

 

 

 

 

 

 

 

 

Used to get/set the option if to

 

0 - don't send

“0” - don't send

snmpsendunrecogniz

send unrecognized events.

Both

edevents

Used only when

1 - send

“1” - send

 

 

snmptrapformat is set to 1.

 

 

 

 

 

 

 

 

 

Used to get/set the option if to

 

“0” - don't send

“0” - don't send

selformat

send unrecognized events.

Both

Used only when

“1” - send

“1” - send

 

 

 

snmptrapformat is set to 1.

 

 

 

 

 

 

 

 

 

Used to get/set the option if to

 

“0” - don't display

“0” - don't display

seldisplayunrecogniz

display unrecognized events

Both

edevents

in SEL. Used only when

“1” - display

“1” - display

 

 

selformat is set to 1.

 

 

 

 

 

 

 

 

 

Used to query the current

 

 

 

temperaturelevel

temperature level of the

Get

“Normal”, “Minor”, “Major”, “Critical”

N/A

 

fantray.

 

 

 

 

 

 

 

 

Table 28. Dataitem Keywords for System Location

dataitem

Description

Get/

 

CLI Get Output

Valid Set Values

Set

 

 

 

 

 

 

 

 

 

 

 

 

 

 

"Critical : CritList

 

 

Used to query which

 

Major

: MajList

 

 

 

Minor

: MinList"

 

unhealthylocations

locations have active health

Get

N/A

 

events

 

where each list is a list of locations

 

 

 

 

having that level of health events

 

 

 

 

(space separated)

 

 

 

 

 

 

 

clearmajor

Clear major alarm LED on

Set

N/A

 

1 - Only accepts a

the active CMM.

 

value of 1

 

 

 

 

 

 

 

 

 

 

clearminor

Clear minor alarm LED on

Set

N/A

 

1 - Only accepts a

the active CMM.

 

value of 1

 

 

 

 

 

 

 

 

 

 

92MPCMM0001 Chassis Management Module Software Technical Product Specification

Page 92
Image 92
Intel MPCMM0001 manual Dataitem Keywords for Cmm Location Sheet 7, Dataitem Keywords for System Location