SNMP

Table 64. CmmTable/cmmEntry (1.3.6.1.4.1.343.2.14.2.10.3.51.1) (Sheet 1 of 2)

OID

Object

Syntax

Access

Value

 

 

 

 

 

1

cmmTarget

DisplayString

none

index

 

 

 

 

 

2

cmmCurrent

DisplayString

read-only

The current value of a sensor.

 

 

 

 

 

3

cmmThresholdsAll

DisplayString

read-only

All thresholds of a sensor.

 

 

 

 

 

4

cmmUpperCritical

DisplayString

read-only

Upper critical thresholds

 

 

 

 

 

5

cmmUpperNonCritical

DisplayString

read-only

upper non-critical thresholds

 

 

 

 

 

6

cmmLowerNonCritical

DisplayString

read-only

lower non-critical thresholds

 

 

 

 

 

7

cmmLowerCritical

DisplayString

read-only

lower critical thresholds

 

 

 

 

 

8

cmmUpperNonRecoverable

DisplayString

read-only

upper non recoverable thresholds

 

 

 

 

 

9

cmmLowerNonRecoverable

DisplayString

read-only

lower non recoverable thresholds

 

 

 

 

 

10

cmmMaximumExternalAvaila

DisplayString

read-write

Each unit is 100mA

bleCurrent

 

 

 

 

 

 

 

 

 

11

cmmMaximumInternalAvailabl

DisplayString

read-only

Each unit is 100mA

 

eCurrent

 

 

 

12

cmmMinimumExpectedOpera

DisplayString

read-write

Each unit is 0.5 Volt

tingVoltage

 

 

 

 

 

 

 

 

 

 

 

 

 

Health information about a particular

13

cmmSensorHealth

INTEGER

read-only

location/sensor. This will be one of the

following: (0-OK, 1-Minor, 2-Major, 3-

 

 

 

 

 

 

 

 

Critical)

 

 

 

 

 

 

 

 

 

Events that contribute to the health of

14

cmmSensorHealthEvents

DisplayString

read-only

the location/sensor. This is a list of

 

 

 

 

events happening on the location.

 

 

 

 

 

15

cmmMinorAction

OCTET

read-write

Used to configure user defined actions

STRING

when minor events occur.

 

 

 

 

 

16

cmmMajorAction

OCTET

read-write

Used to configure user defined actions

STRING

when major events occur.

 

 

 

 

 

17

cmmCriticalAction

OCTET

read-write

Used to configure user defined actions

 

 

STRING

 

when critical events occur.

18

cmmNormalAction

OCTET

read-write

Used to configure user defined actions

 

 

STRING

 

when normal events occur.

35

cmmfruBoardDescription

DisplayString

read-only

Used to read the Board Description

from the FRU.

 

 

 

 

 

 

 

 

 

36

cmmfruBoardManufacturer

DisplayString

read-only

Used to read the Board Manufacturer

from the FRU.

 

 

 

 

 

 

 

 

 

37

cmmfruBoardPartNumber

DisplayString

read-only

Used to read the Board Part Number

from the FRU.

 

 

 

 

 

 

 

 

 

38

cmmfruBoardSerialNumber

DisplayString

read-only

Used to read the Board Serial Number

from the FRU.

 

 

 

 

 

 

 

 

 

39

cmmfruBoardManufactureDat

DisplayString

read-only

Used to read the Board Manufacture

e

Date from the FRU.

 

 

 

 

 

 

 

 

40

cmmfruProductDescription

DisplayString

read-only

Used to read the Product Description

from the FRU.

 

 

 

 

 

 

 

 

 

41

cmmfruProductManufacturer

DisplayString

read-only

Used to read the Product Manufacturer

from the FRU.

 

 

 

 

 

 

 

 

 

42

cmmfruProductPartNumber

DisplayString

read-only

Used to read the Product Part Number

from the FRU.

 

 

 

 

 

 

 

 

 

MPCMM0001 Chassis Management Module Software Technical Product Specification

149

Page 149
Image 149