Health Events

Table 48. Process Monitoring Service Info Event Strings (PMS Info)

Event String

Event Code

Event Severity

Hex

 

Decimal

 

 

 

 

 

 

 

 

 

"Take no action specified for recovery"

0x0179

 

377

User-Configurable

 

 

 

 

 

"Attempting process restart recovery action"

0x017A

 

378

User-Configurable

 

 

 

 

 

"Attempting process failover & restart recovery action"

0x017B

 

379

User-Configurable

 

 

 

 

 

"Attempting process failover & reboot recovery action"

0x017C

 

380

User-Configurable

 

 

 

 

 

"Take no action specified for escalated recovery"

0x017D

 

381

User-Configurable

 

 

 

 

 

"Attempting failover & reboot escalated recovery action"

0x017E

 

382

User-Configurable

 

 

 

 

 

"Process restart recovery failure"

0x017F

 

383

User-Configurable

 

 

 

 

 

"Failover & reboot recovery failure"

0x0180

 

384

User-Configurable

 

 

 

 

 

"Recovery failure due to excessive restarts"

0x0181

 

385

User-Configurable

 

 

 

 

 

"Failover & reboot escalated recovery failure"

0x0182

 

386

User-Configurable

 

 

 

 

 

"Internal fault detected; monitoring disabled"

0x0183

 

387

User-Configurable

 

 

 

 

 

Note: PMS Info events are only written to the SEL, not SNMP traps, healthevents, LEDs, or telco alarms.

11.4.3Chassis Location

Table 49. Chassis Events

Event String

Event Code

Event Severity

Hex

 

Decimal

 

 

 

 

 

 

 

 

 

"cmm.sif file not found. Cannot scan CMM sensors."

0x0101

 

257

Major

 

 

 

 

 

"chassis.sif file not found. Cannot scan Chassis sensors."

0x0102

 

258

Major

 

 

 

 

 

11.5IPMI Error Completion Codes

Whereas versions of firmware prior to 5.2 gave a single error message for any IPMI communication issue, Version 5.2 firmware and above implements more granular IPMI error code reporting, allowing the return of the exact IPMI error code that is returned by the IPMI message response. This is specified in the IPMI 1.5 specification as the first byte in the data field of the IPMI response. This allows more accurate analysis to be done in regards to the IPMI communication between the CMM and a IPMI sensor/device.

The following table shows the IPMI Completion codes from the IPMI 1.5 specification as well as their respective enumeration and error message given by the CMM.

120MPCMM0001 Chassis Management Module Software Technical Product Specification

Page 120