FRU Update Configuration File

Table 104. FRU Field First String Specifications

FRU Field First

String Description

ASCII String

 

 

 

 

Chassis Type (Chassis Area) The input string must represent a number. Regardless of the

“CT”

input type specified in the configuration file. This is because the chassis type field is an

encoded value and is limited in range. The utility shall limit the input to the valid range and

 

 

interpret the value correctly when decoding.

 

 

“MN”

Manufacturer Name (Board and Product Areas)

 

 

“PN”

Product Name (Board and Product Areas)

 

 

“P#”

Part Number (Chassis, Board and Product Areas)

 

 

“S#”

Serial Number (Chassis, Board and Product Areas)

 

 

“PV”

Product Version (Product Area)

 

 

“AT”

Asset Tag (Product Area)

 

 

“ID”

Manufacturer ID (Board and Product Areas)

 

 

 

Manufacturing Date & Time (Board Area). Date and time are supplied by the Server,

“MD”

therefore no arguments are allowed following “MD”. This field shall not be updated by the

 

utility; as so, the utility should error when this field is selected for an update.

 

 

“AMx”

Additional Manufacturing Info (Chassis, Board and Product Areas) There can be

multiple instances of this field, where ‘x’ represents a decimal number from 1-9.

 

 

 

If you specify the “MD” field, then the date and time will be updated from the server. If you add any arguments after the “MD” field, then an error will be displayed.

Table 105 defines the maximum length of the fields that shall be allowed by the utility. The load utility may force the input to be shorter if there is not enough room in the FRU area to support the maximum length of the FRU field.

Table 105. FRU Field Maximum Allowed Lengths (Sheet 1 of 2)

FRU Fields

FRU Field Max Allowed Length

 

 

Product Manufacturer

1Fh bytes

 

 

Product Name

1Fh bytes

 

 

Product Part Number

17h bytes

 

 

Product Version Number

1Fh bytes

 

 

Product Serial Number

1Fh bytes

 

 

Product Version

1Fh bytes

 

 

Product FRU Field ID

1Fh bytes

 

 

Product Custom Fields (AMx)

1Fh bytes

 

 

Board Manufacturer

1Fh bytes

 

 

Board Product Name

1Fh bytes

 

 

Board Part Number

17h bytes

 

 

Board Serial Number

1Fh bytes

 

 

Board FRU Field ID

1Fh bytes

 

 

Board Custom Fields (AMx)

1Fh bytes

 

 

Chassis Type

1h byte

 

 