1.Connect one end of the grounding cable to a proper earth ground, such as the rack in which the switch is mounted.

2.Place the grounding lug attached to the grounding cable over the protective earthing terminal. See Figure 25 on page 67.

3.Secure the grounding lug to the protective earthing terminal with screws.

4.Dress the grounding cable and ensure that it does not touch or block access to other switch components and that it does not drape where people could trip over it.

Connecting Earth Ground to an EX8216 Switch

There are two protective earthing terminals on an EX8216 switch: one on the left side of the chassis and the other on the rear of the chassis. Only one of the two protective earthing terminals needs to be permanently connected to earth ground.

An AC-powered EX Series switch chassis gets additional grounding when you plug the power supply in the switch into a grounded AC power outlet by using an AC power cord appropriate for your geographical location. See AC Power Cord Specifications for an EX8200 Switch.

Ensure that you have the following parts and tools available:

Grounding cable for your EX8216 switch—The grounding cable must be 2 AWG (33.6 mm²), minimum 60°C wire, or as permitted by the local code.

Grounding lug for your grounding cable. See Grounding Cable and Lug Specifications for EX8200 Switches.

Washers and ¼-20x.5/8-in. screws to secure the grounding lug to the protective earthing terminal

Phillips (+) screwdriver, number 2

To connect earth ground to an EX8216 switch:

1.Connect one end of the grounding cable to a proper earth ground, such as the rack in which the switch is mounted.

2.Place the grounding lug attached to the grounding cable over the protective earthing terminal. See Figure 25 on page 67.

3.Secure the grounding lug to the protective earthing terminal with screws.

4.Dress the grounding cable and ensure that it does not touch or block access to other switch components and that it does not drape where people could trip over it.

Related Connecting AC Power to an EX2200 Switch on page 73

Documentation

Connecting AC Power to an EX3200 Switch

Connecting DC Power to an EX3200 Switch

Connecting AC Power to an EX4200 Switch

Connecting DC Power to an EX4200 Switch

72

Copyright © 2010, Juniper Networks, Inc.

Page 92
Image 92
Juniper Networks EX2200 manual Connecting Earth Ground to an EX8216 Switch