Chapter 4: Site Preparation

Ensure that these environmental guidelines are followed:

The site must be as dust-free as possible, because dust can clog air intake vents and filters, reducing the efficiency of the switch cooling system.

Maintain ambient airflow for normal switch operation. If the airflow is blocked or restricted, or if the intake air is too warm, the switch might overheat, leading to the switch temperature monitor shutting down the switch to protect the hardware components.

Table 17 on page 37 provides the required environmental conditions for normal switch operation.

Table 17: EX Series Switch Environmental Tolerances

Description

Tolerance

Altitude

No performance degradation to 10,000 feet (3048 meters)

Relative humidity

Normal operation ensured in relative humidity range of 10% through 85%, noncondensi

Temperature

EX2200, EX3200, EX4200, and EX4500 switches: Normal operation ensured in temp

 

through 113° F (0° C through 45° C)

 

EX8208 and EX8216 switches: Normal operation ensured in temperature range of 32°

 

through 40° C)

 

XRE200 External Routing Engines: Normal operation ensured in temperature range of

 

(5° C through 40° C)

Seismic

Complies with Zone 4 earthquake requirements as per GR-63, Issue 3.

 

NOTE: Install EX Series switches only in restricted areas, such as dedicated

 

equipment rooms and equipment closets, in accordance with Articles 110–16,

 

110–17, and 110–18 of the National Electrical Code, ANSI/NFPA 70.

Related

Clearance Requirements for Airflow and Hardware Maintenance for EX2200 Switches

Documentation

on page 42

 

Clearance Requirements for Airflow and Hardware Maintenance for EX3200 Switches

 

Clearance Requirements for Airflow and Hardware Maintenance for EX4200 Switches

 

Clearance Requirements for Airflow and Hardware Maintenance for EX4500 Switches

 

Clearance Requirements for Airflow and Hardware Maintenance for an EX8208 Switch

 

Clearance Requirements for Airflow and Hardware Maintenance for an EX8216 Switch

Copyright © 2010, Juniper Networks, Inc.

37

Page 57
Image 57
Juniper Networks EX2200 manual EX Series Switch Environmental Tolerances, Description Tolerance