Replacing Consumables

Note

Before removing the photoconduc- tor unit from the printer, spread paper or some other material around the area you are working to keep the toner from making the floor dirty.

The “Change PCU” message is based on a printed page counter kept internally by the printer. It is meant as a general guide to photo- conductor unit life only. Actual photoconductor unit life depends on the printing conditions.

A Make sure that the Data In indica- tor is not lit or flashing, and then press the printer's power switch to turn off the power.

B Open the front cover by pulling the front cover open lever and open the top cover by pulling the top cover open lever.

ZDGH110J

Important

Be sure to open both the top and front covers before removing the photoconductor unit. Fail- ure to do so can result in dam- ag e to the surface of the photoconductor unit.

Note

If the printer is equipped with the paper feed unit (optional) and the duplex unit (optional), first open the upper portion of the duplex unit, and then open the top cover of the printer.

C Stand up the green lock levers to a vertical position.

4

ZDGH120J

D Hold the inset grip of the photo- conductor unit, pull it straight up, and remove it from the printer.

ZDGH130J

E Remove the new photoconductor unit from the box.

69

Page 82
Image 82
Lanier AP206 manual Stand up the green lock levers to a vertical position, Remove the new photoconductor unit from the box