Change Software

Examples

CHANGE SNMPSETCOMM WPHRED

 

(adds a single community with read-write access)

See Also

The Configuration chapter of your Installation Guide

2.57 Change Software

CHANGE SERVER SOFTWARE filename

Specifies the name of the download file that, when a reload has been requested, the MSS will attempt to load at boot time.

Restrictions

Requires privileged user status.

ParametersServer

MSS4 only.

filename

Specify a loadfile name of 11 or fewer characters. The server will automatically add a .SYS extension to the file name. You can also enter the complete pathname if the file is to be loaded via TFTP; place the filename in quotes to preserve case.

See Also

Change Loadhost, page 2-29.

2.58 Change Speed

CHANGE PORT PortList SPEED rate

Specifies the baud rate of the serial port.

Restrictions

Requires privileged user status.

Errors

An error is displayed if an unsupported baud rate is specified.

Parameters

Port

 

MSS4 only. Specifies a particular port or group of ports.

Note:

In the absence of the PortList parameter, the configuration will affect the MSS4’s

 

current port only.

 

PortList

 

Specify a particular port or group of ports. Port numbers are specified with

 

integers between 1 and 4, and should be separated with commas (for lists) or

 

dashes (for ranges).