Lantronix MSS manual Change Loginpass, Change Modem Control

Models: MSS

1 91
Download 91 pages 19.23 Kb
Page 40
Image 40

Command Reference

Change Loginpass

2.31 Change Loginpass

CHANGE SERVER LOGINPASS passwd

Specifies the password used to log into the MSS. The password should consist of no more than 6 alphabetic letters. Users are only required to provide this password if the port has Password Protect enabled.

If you do not enter the password at the command line, you will immediately be prompted to enter the new password. This password is not displayed when typed.

Restrictions

Requires privileged user status.

Parameters

Server

 

MSS4 only.

 

passwd

 

Enter a password of up to 6 alphabetic characters. When entered as part of the

 

command, the password should be enclosed by quotation marks to preserve

 

case.

Defaults

access

Examples

CHANGE LOGINPASS “badger”

See Also

Change Password Protect, page 2-38; Change Incoming, page 2-26.

2.32 Change Modem Control

DISABLED

CHANGE PORT PortList MODEM CONTROL   ENABLED

Causes the MSS to treat any attached serial device as a modem. When enabled, a DSR drop will log out the enabled port and the MSS will drop DTR for three seconds and then raise it when the port logs out. If Autostart is also enabled, the port will not start until DSR is raised. The MSS supports partial modem control (DSR/DTR).

Restrictions

Requires privileged user status.

 

Does not apply to the MSS485.

Errors

Modem Control must be disabled to use DSRLogout.

Parameters

Port

 

MSS4 only. Specifies a particular port or group of ports.

Note:

In the absence of the PortList parameter, the configuration will affect the MSS4’s

 

current port only.

2-31

Page 40
Image 40
Lantronix MSS manual Change Loginpass, Change Modem Control