7.6 SCSI Timings

Tables 7.17 through 7.23 and Figures 7.19 through 7.23 describe the LSI53C810A SCSI timing data.

Table 7.17 Initiator Asynchronous Send (5 Mbytes/s)

Symbol

Parameter

Min

Max

Unit

 

 

 

 

 

t1

SACK/ asserted from SREQ/ asserted

10

ns

 

 

 

 

 

t2

SACK/ deasserted from SREQ/ deasserted

10

ns

t3

Data setup to SACK/ asserted

55

ns

t4

Data hold from SREQ/ deasserted

20

ns

Figure 7.19 Initiator Asynchronous Send

SREQ/

SACK/

SD[7:0],

SDP/

t1

n

t3

Valid n

n + 1

t2

n + 1

t4

Valid n + 1

SCSI Timings

7-27

Page 209
Image 209
LSI 53C810A technical manual Scsi Timings, Initiator Asynchronous Send 5 Mbytes/s