SCSI Input Data Latch (SIDL), SCSI Output Data Latch (SODL), and SODR full bits in the SCSI Status Zero (SSTAT0) register are cleared.

STWSCSI FIFO Test Write0

Setting this bit places the SCSI core into a test mode in which the FIFO is easily written. While this bit is set, writes to the SCSI Output Data Latch (SODL) register cause the entire word contained in this register to be loaded into the FIFO. Writing the least significant byte of the SCSI Output Data Latch (SODL) register causes the FIFO to load.

Register: 0x50 (0xD0)

SCSI Input Data Latch (SIDL)

Read Only

15

0

SIDL

x x x

x

x

x

x

x

x

x

x

x

 

 

 

 

x

x

x

x

SIDLSCSI Input Data Latch[15:0]

This register is used primarily for diagnostic testing, programmed I/O operation, or error recovery. Data received from the SCSI bus can be read from this register. Data can be written to the SCSI Output Data Latch (SODL) register and then read back into the LSI53C810A by reading this register to allow loopback testing. When receiving SCSI data, the data flows into this register and out to the host FIFO. This register differs from the SCSI Bus Data Lines (SBDL) register; SCSI Input Data Latch (SIDL) contains latched data and the SCSI Bus Data Lines (SBDL) always contains exactly what is currently on the SCSI data bus. Reading this register causes the SCSI parity bit to be checked, and causes a parity error interrupt if the data is not valid. The power-up values are indeterminate.

5-65

Page 139
Image 139
LSI 53C810A technical manual Register 0x50 0xD0, Stwscsi Fifo Test Write0, Scsi Input Data Latch Sidl Read Only