Table 7.19 Target Asynchronous Send (5 Mbytes/s)

Symbol

Parameter

Min

Max

Unit

 

 

 

 

 

t1

SACK/ asserted from SREQ/ asserted

10

ns

 

 

 

 

 

t2

SACK/ deasserted from SREQ/ deasserted

10

ns

 

 

 

 

 

t3

Data setup to SREQ/ asserted

55

ns

 

 

 

 

 

t4

Data hold from SACK/ asserted

20

ns

 

 

 

 

 

Figure 7.21 Target Asynchronous Send

SREQ/

n

 

t1

SACK/

n

 

t3

t4

SD[7:0],

Valid n

SDP/

 

n + 1

t2

n + 1

Valid n + 1

SCSI Timings

7-29

Page 211
Image 211
LSI 53C810A technical manual Target Asynchronous Send 5 Mbytes/s