EISEnable I/O Space0

This bit controls the LSI53C810A’s response to I/O space accesses. A value of zero disables the response. A value of one allows the LSI53C810A to respond to I/O space accesses at the address specified in Base Address Zero (I/O).

Register: 0x06

Status

Read/Write

15

14

13

12

11

10

9

8

7

 

 

 

 

 

 

 

0

DPE

SSE

RMA

RTA

R

DT[1:0]

DPR

 

 

 

 

R

 

 

 

0

0

0

0

0

0

0

0

0

0

0

0

 

0

0

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The Status register is used to record status information for PCI bus-related events.

In the LSI53C810A, bits 0 through 4 are reserved and bits 5, 6, 7, and 11 are not implemented.

Reads to this register behave normally. Writes are slightly different in that bits can be cleared, but not set. A bit is cleared whenever the register is written, and the data in the corresponding bit location is a one. For instance, to clear bit 15 and not affect any other bits, write the value 0x8000 to the register.

DPE

Detected Parity Error (from Slave)

15

 

This bit is set by the LSI53C810A whenever it detects a

 

data parity error, even if parity error handling is disabled.

SSE

Signaled System Error

14

 

This bit is set whenever a device asserts the SERR/

 

 

signal.

 

RMA

Master Abort (from Master)

13

 

A master device should set this bit whenever its

 

transaction (except for Special Cycle) is terminated with master-abort. All master devices should implement this bit.

Configuration Registers

3-13

Page 55
Image 55
LSI 53C810A technical manual EISEnable I/O Space0, Status Read/Write, Dpe, Sse, Rma