FXS Loop Start Interface: Parameter Definitions (cont’d)

Field Name

Values

Description

Dialing Options fields

 

 

 

 

Inter Digit

1 - 10 seconds

This is the length of time that

Timer

 

the MultiVOIP will wait

 

 

between digits. When the time

 

 

expires, the MultiVOIP will

 

 

look in the outbound

 

 

phonebook for the number

 

 

entered and place the call

 

 

accordingly.

 

 

Default = 2.

 

 

 

Message

--

Not applicable to FXS Loop

Waiting

 

Start interface

Indication

 

 

 

 

 

Inter Digit

in milliseconds

The length of time between the

Regeneration

 

outputting of DTMF digits.

Time

 

Default = 100 ms.

 

 

 

 

 

FXS Options fields

 

 

 

 

FXS Ring

1-99

Maximum number of rings that

Count , FXS

 

the MultiVOIP will issue before

 

 

giving up the attempted call.

Current Loss

Y/N

When enabled, the MultiVOIP

 

 

will interrupt loop current in

 

 

the FXS circuit to initiate a

 

 

disconnection. This tells the

 

 

device connected to the FXS

 

 

port to hang up. The Multi-

 

 

VOIP cannot drop the call; the

 

 

FXS device must go on hook.

Generate

Y/N

When selected, this option

Current

 

implements Answer

Reversal

 

Supervision and Disconnect

 

 

Supervision to the FXO

 

 

interface using current reversal

 

 

to indicate events. Applicable

 

 

only when FXS and FXO

 

 

interfaces are connected back to

 

 

back.