Multi-Tech Systems MVP210-SS manual 144, Tone

Models: MVP210-SS

1 415
Download 415 pages 23.09 Kb
Page 144
Image 144

Technical Configuration

MultiVOIP User Guide

 

 

E&M Interface Parameter Definitions

Field Name

Values

Description

Interface

E&M

enables E&M functionality

 

 

 

Type

Types 1-5.

Refers to the type of E&M

 

 

interface being used.

 

 

 

Mode

2-wire or 4-wire

Each E&M interface type can be

 

 

either 2-wire or 4-wire audio.

 

 

 

Signal

Dial Tone or

When Dial Tone is selected, no

 

Wink

wink is required on the E lead

 

 

or M lead in the call initiation or

 

 

setup.

 

 

When Wink is selected, a wink

 

 

is required during call setup.

 

 

 

Wink Timer

integer values,

This is the length of the wink

(in ms)

in milliseconds

for wink signaling.

 

 

Applicable only when Signal

 

 

parameter is set to “Wink.”

 

 

 

No Response

integer values (in

The value here denotes the time

Timer

seconds)

(in seconds) after which the call

 

 

attempt would be disconnected

 

 

by the FXO Interface because

 

 

there was no answer.

 

 

 

Disconnect on

Y/N

Allows call on FXO port to be

Call Progress

 

disconnected when a PBX issues a

Tone

 

call-progress tone denoting that

 

 

the phone station on the PBX that

 

 

has been involved in the call has

 

 

been hung up.

 

 

 

Pass Through

Y/N

When enabled (“Y”), this

Enable

 

feature is used to create an open

 

 

audio path for 2- or 4-wire. The

 

 

E&M leads are passed through

 

 

the voip transparently.

 

 

Applicable only for E&M

 

 

Signaling with Dial Tone (not

 

 

applicable for Wink signaling).

 

 

 

144

Page 144
Image 144