Technical Configuration

MultiVOIP User Guide

 

 

SIP Call Signaling Parameter Definitions

(cont’d)

Field Name

Values & Description

SIP Proxy Parameters

Password

Values: alphanumeric

 

Description: Password for proxy server

 

function. See “User Name” description

 

above.

 

 

 

 

Re-

Values: numeric (in seconds)

Registration

Description: This is the timeout interval for

Time

registration of the MultiVOIP with a SIP

 

proxy server. The time interval begins the

 

moment the MultiVOIP gateway registers

 

with the SIP proxy server and ends at the

 

time specified by the user in the Re-

 

Registration Time field (this field). When/if

 

registration lapses, call traffic routed to/from

 

the MultiVOIP through the SIP proxy server

 

will cease. However, calls in progress will

 

continue to function until they end.

 

 

 

Proxy Polling

integer

The interval between the voip

Interval

60 - 300

gateway’s successive attempts to

 

 

connect to and be governed by a

 

 

higher level SIP proxy server. The

 

 

Primary Proxy is the highest level

 

 

gatekeeper. Alternate Proxy 1 is

 

 

second; Alternate Proxy 2 is the

 

 

lowest order SIP proxy server.

TTL Value

The SIP proxy “Time to Live” value. As soon as a

in seconds

MultiVOIP gateway registers with a SIP proxy

 

server (allowing the proxy server to control its call

 

traffic) a countdown timer begins. The TTL Value

 

is the interval of the countdown timer. Before the

 

TTL countdown expires, the MultiVOIP gateway

 

needs to register with the gatekeeper in order to

 

maintain the connection. If the MultiVOIP does

 

not register before the TTL interval expires, the

 

MultiVOIP gateway’s registration with the proxy

 

server will expire and the proxy server will no

 

longer permit call traffic to or from that gateway.

 

Calls in progress will continue to function even if

 

the gateway becomes de-registered.