4.You now need to free up the COM port connection (currently being used by the MultiVOIP program) so that the HyperTerminal program can use it. To do this, you can either (a) click on Connection in the sidebar and select “Disconnect” from the drop-down box, or (b) close down the MultiVOIP program altogether.

5.Open the HyperTerminal program.

6.Use HyperTerminal to receive and record console messages from the MultiVOIP unit. To do so, set up HyperTerminal as follows (setup shown is for Windows NT4; details will differ slightly in other MS operating systems):

In the upper toolbar of the HyperTerminal screen, click on the Properties button.

In the “Connect To” tab of the Connection Properties dialog box, click on the Configure button.

In the next dialog box, on the “General” tab, set “Maximum Speed” to 115200 bps.

On the “Connection” tab, set connection preferences to:

Data bits: 8

Parity: none

Stop bits: 1

Click OK twice to exit settings dialog boxes.