Multi-Tech Systems MVP210-SS manual 302

Models: MVP210-SS

1 415
Download 415 pages 23.09 Kb
Page 302
Image 302

Operation & Maintenance

MultiVOIP User Guide

 

 

 

 

 

 

 

 

 

 

 

Logs Screen Details: Field Definitions (cont’d)

 

 

 

 

 

 

 

Field Name

Values

Description

 

 

Call

Details

 

 

 

Voice coder

G.723, G.729,

The voice coder being used on

 

 

 

G.711, etc.

this call.

 

 

Disconnect

Values are

Indicates whether the call was

 

 

Reason

"Normal" and

disconnected simply because the

 

 

 

"Local"

desired conversation was done

 

 

 

disconnection.

or some other irregular cause

 

 

 

 

occasioned disconnection (e.g., a

 

 

 

 

technical error or failure).

 

 

DTMF Capability

inband,

Indicates whether the DTMF dialing

 

 

 

out of band

digits are carried "Inband" or "Out of

 

 

 

Expressions

Band." The corresponding field

 

 

 

values differ for the 3 different voip

 

 

 

differ slightly

 

 

 

protocols.

 

 

 

for different

 

 

 

For H.323, this field can display "Out

 

 

 

Call Signaling

 

 

 

of Band" or "Inband". For SIP it can

 

 

 

protocols

 

 

 

display either "Out of Band RFC2833"

 

 

 

(H.323, SIP, or

 

 

 

or "Out of Band SIP INFO" to

 

 

 

SPP).

 

 

 

indicate the out-of-band condition or

 

 

 

 

 

 

 

 

"Inband" to indicate the in-band

 

 

 

 

condition. For SPP it can display

 

 

 

 

"Out of Band RFC2833" or "Inband".

 

 

Outbound Digits

0-9, #, *

The digits, sent by MultiVOIP to

 

 

Received

 

PBX/telco, that were

 

 

 

 

acknowledged as having been

 

 

 

 

received by the remote voip

 

 

 

 

gateway.

 

 

Outbound Digits

0-9, #, *

The digits transmitted by the

 

 

Sent

 

MultiVOIP to the PBX/telco for

 

 

 

 

this call.

 

302

Page 302
Image 302
Multi-Tech Systems MVP210-SS manual 302