Technical Configuration

 

 

 

 

 

 

 

 

 

E&M Interface Parameter Definitions (cont’d)

 

 

 

 

 

Field Name

Values

Description

 

 

 

 

 

Dialing Options

 

 

 

 

 

 

Inter Digit

integer values,

This is the length of time that

 

Timer

in seconds

the MultiVOIP will wait

 

 

 

between digits. When the time

 

 

 

expires, the MultiVOIP will

 

 

 

look in the phonebook for the

 

 

 

number entered. Default = 2.

 

 

 

 

 

Message

Light or None

Allows MultiVOIP to pass

 

Waiting

 

mode-code sequences between

 

Indication

 

Avaya Magix PBXs to turn on

 

 

 

and off the message-waiting

 

 

 

light on a PBX extension phone.

 

 

 

Mode codes:

 

 

 

*53 + PBX extension

 

 

 

Î turns message light on.

 

 

 

#53 + PBX extension

 

 

 

Î turns message light off.

 

 

 

Signals to turn message-waiting

 

 

 

lights on/off are not sent to

 

 

 

phones connected directly to

 

 

 

the MultiVOIP on FXS

 

 

 

channels, not to other non-

 

 

 

Avaya Magix PBX phone

 

 

 

stations on the voip network.

 

 

 

 

 

Inter Digit

milliseconds

The length of time between the

 

Regeneration

 

outputting of DTMF digits.

 

Timer

 

Default = 100 ms.

 

 

 

 