QS: Connectivity Test

 

 

Console Messages from Terminating VOIP. The voip unit connected to the phone where the call is answered will send back messages like that shown below.

[00170860]

H323[0]: New incoming call

[00170860]

PSTNIF : Placing call on channel 0 Outbound

 

digit 7175662

[00170885]

CAS[0] : TX : ABCD = 1, 1, 1, 1

[00171095]

H323IF [0]: MasterSlaveStatus=Master

[00171105]

CAS[0] : RX : ABCD = 1, 1, 1, 1,Pstn State[7]

 

TimeStamp : 171105

[00171105]

H323IF[0]: Coder used 'g7231'

[00171110]

H323IF[0]:FastStart Setup Not Used

[00171110]

H323IF[0]: Already opened the outgoing logical

 

channel

[00171110]

H323IF[0]: Coder used 'g7231'

[00171315]

CAS[0] : RX : ABCD = 0, 0, 0, 0,Pstn State[9]

 

TimeStamp : 171315

[00172275]

PSTN: dialing digit ended on 0

[00172285]

PSTN: pstn proceeding indication on 0

[00172995]

CAS[0] : RX : ABCD = 1, 1, 1, 1,Pstn State[12]

 

TimeStamp : 172995

[00173660]

CAS[0] : TX : ABCD = 1, 1, 1, 1

[00173760]

PSTN:pstn call connected on 0

9.When you see the following message, end-to-end voip connectivity has been achieved.

PSTN: pstn call connected on X

where x is the number of the voip channel carrying the call

10.If the HyperTerminal messages do not confirm connectivity, go to the Troubleshooting procedure below.