Multi-Tech Systems MVP210-SS manual 134, Dialing Options

Models: MVP210-SS

1 415
Download 415 pages 23.09 Kb
Page 134
Image 134

Technical Configuration

MultiVOIP User Guide

 

 

FXO Interface: Parameter Definitions*

Field Name

Values

Description

Interface Type

FXO

Enables FXO functionality

 

 

 

Dialing Options

 

 

 

 

Regeneration

Pulse, DTMF

Determines whether digits

 

 

generated and sent out will be

 

 

pulse tones or DTMF.

 

 

 

Inter Digit

1 to 10 seconds

This is the length of time that

Timer

 

the MultiVOIP will wait

 

 

between digits. When the time

 

 

expires, the MultiVOIP will

 

 

look in the phonebook for the

 

 

number entered.

 

 

Default = 2.

 

 

 

Message

--

Not applicable to FXO interface.

Waiting

 

 

Indication

 

 

 

 

 

Inter Digit

50 to 20,000

The length of time between the

Regeneration

milliseconds

outputting of DTMF digits.

Time

 

Default = 100 ms.

 

 

 

FXO Options

 

 

 

 

FXO Ring

1-99

Number of rings required

Count

 

before the MultiVOIP answers

 

 

the incoming call.

 

 

 

No Response

1 – 65535

Length of time before call

Timer

(in seconds)

connection attempt is

 

 

abandoned.

 

 

 

134

Page 134
Image 134
Multi-Tech Systems MVP210-SS manual 134, Dialing Options