Interface output signals - #1100–#1115, #1132

16 interface output signals can be issued, one by one, by assigning values to variables #1100 through #1115.

Name of system variables

Interface input with reference to the

 

PLC program

#1100

Y[CONST+000]

#1101

Y[CONST+001]

#1102

Y[CONST+002]

#1103

Y[CONST+003]

#1104

Y[CONST+004]

#1105

Y[CONST+005]

#1106

Y[CONST+006]

#1107

Y[CONST+007]

#1108

Y[CONST+010]

#1109

Y[CONST+011]

#1110

Y[CONST+012]

#1111

Y[CONST+013]

#1112

Y[CONST+014]

#1113

Y[CONST+015]

#1114

Y[CONST+016]

#1115

Y[CONST+017]

where CONST=O_LINE*10 and O_LINE is a parameter. Thus, any arbitrary interface output word can be issued or read.

The values of the above variables may be 0= the contact at the output is open, 1= the contact at the output is closed.

The above 16 outputs can be issued simultaneously by using variable #1132. Depending on the system variables assigned to the single outputs, the output value will be

Accordingly, with outputs #1102 and #1109 are on, the rest of outputs being off, variable #1132 must output the value