2 Controlled Axes

The rotational axes are always provided with degrees as units of measure.

The input increment system of the control is regarded as the smallest unit to be entered. It can be selected as parameter. There are three systems available - IS-A IS-B and IS-C. The increment systems may not be combined for the axes on a given machine.

Having processed the input data, the control system will provide new path data for moving the axes. Their resolution is always twice the particular input increment system. It is termed the output increment system of the control.

Thus the input increment system of the control is determined by the resolution of the encoder.

 

 

 

 

Increment system

Min. unit to be entered

Max. unit to be entered

 

 

0.01 mm

999999.99 mm

 

IS-A

0.001 inch

99999.999 inch

 

 

0.01 degree

999999.99 degree

 

 

0.001 mm

99999.999 mm

 

IS-B

0.0001 inch

9999.9999 inch

 

 

0.001 degree

99999.999 degree

 

 

0.0001 mm

9999.9999 mm

 

IS-C

0.00001 inch

999.99999 inch

 

 

0.0001 degree

9999.9999 degree

 

 

 

 

 