6 The Feed

The feed value (F) is modal. After power-on, the feed value set at parameter FEED will be effective.

6.2.1 Feed per Minute (G94) and Feed per Revolution (G95)

The unit of feed can be specified in the program with the G94 and G95 codes: G94: feed per minute

G95: feed per revolution

The term "feed/minute" refers to a feed specified in units mm/minute, inch/minute or degree/minute. The term "feed/rev" refers to the feed accomplished in a revolution of the spindle, in units of mm/rev, inch/minute or deg/rev. A G95 cannot be programmed unless the spindle is equipped with an encoder.

Modal values. After power-on, state G94 or G95 will be selected with reference to parameter group CODES. State G94/G95 will be unaffected the rapid traverse, it is invariably in units of minutes.