7 The Dwell

7 The Dwell (G04)

The

(G94) G04 P....

command will program the dwell in seconds. The range of P is 0.001 to 99999.999 seconds.

The

(G95) G04 P....

command will program the dwell in terms of spindle revolutions. The range of P is 0.001 to 99999.999 revolutions.

Depending on parameter SECOND, the delay may refer always to seconds as well, irrespective of the states of G94, G95.

The dwell implies invariably the programmed delay of the execution of the next block. It is a non- modal function.

During dwell in status field 5 indicating interpolation status the message DWL will appear on screen to draw the attention of operator why the machine is halted.