3 Preparatory Functions (G codes)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G code

Group

Function

 

 

Page

 

G80*

 

canned cycle cancel

 

141

 

 

G81

 

drilling, spot boring cycle,

 

141

 

 

G82

 

drilling, counter boring cycle

 

 

142

 

 

 

 

 

 

 

 

 

 

 

G83

 

peck drilling cycle

 

143

 

 

 

 

 

 

 

 

 

 

 

 

 

G84

 

tapping cycle

 

144

 

 

 

 

 

 

 

 

 

 

 

 

 

G84.2

 

rigid tap cycle

 

145

 

 

 

 

 

 

 

 

 

 

 

 

 

G84.3

 

rigid counter tap cycle

 

145

 

 

 

 

 

 

 

 

 

 

 

 

 

G85

 

boring cycle

 

148

 

 

 

 

 

 

 

 

 

 

 

 

 

G86

 

Boring Cycle Tool Retraction with Rapid Traverse

 

149

 

 

G87

 

Boring Cycle/Back Boring Cycle

 

150

 

 

G88

 

Boring Cycle (Manual Operation on the Bottom Point)

 

152

 

 

G89

 

Boring Cycle (Dwell on the Bottom Point, Retraction with Feed)

 

153

 

 

G90*

03

absolute command

 

38

 

 

 

G91*

incremental command

 

38

 

 

 

 

 

 

 

 

G92

00

work coordinates change/maximum spindle speed setting

 

59

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G94*

05

feed per minute

 

46

 

 

 

 

 

 

 

 

 

 

 

 

 

G95*

feed per revolution

 

46

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G96

13

constant surface speed control

 

65

 

 

 

 

 

 

 

 

 

 

 

 

 

G97*

constant surface speed control cancel

 

65

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G98*

10

canned cycle initial level return

 

133

 

 

 

 

 

 

 

 

 

 

 

 

G99

canned cycle R point level return

 

133

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LNotes:

The * marked G codes in a group represent the state assumed by the control system after power- on.

If several codes are marked with * in a group, a parameter can be set to select the effective one after power-on. They are : G00, G01; G17, G18; G43, G44, G49; G90, G91; G94, G95.

At the time of power-on, the particular one of G20 and G21 will be effective, that has been set at the time of power-off.

Default interpretation of command G05.1 after power-on can be specified with the MULBUF parameter.

G codes in group 00 are not modal ones; the rest are so.

More than one G code can be written in a block with the restriction that only one of the same function group may used.

Reference to an illegal G code or specification of several G codes belonging to the same group within a particular block will produce error message 3005 ILLEGAL G CODE.

21

Page 21
Image 21
NCT Group 99M, 2000M manual 141