WAN and System Configuration 2-25
IP Profile Parameters
Address Translation Enabled: | No |
IP Addressing... | Numbered |
Stateful Inspection Enabled: | Yes |
Stateful Inspection Options... |
|
Local WAN IP Address: | 0.0.0.0 |
Local WAN IP Mask: | 0.0.0.0 |
Filter Set... |
|
Remove Filter Set |
|
RIP Profile Options...
Configure IP requirements for a remote network connection here.
Select Stateful Inspection Options and press Return. The Stateful Inspection Parameters screen appears.
Stateful Inspection Parameters
Max. TCP Sequence Number Difference: | 0 |
Enable default mapping to router: | No |
Deny Fragmented Packets: | No |
Exposed Address List... |
|
Enter max. allowed TCP sequence number difference (1 - 65535), 0 to disable.
•Max. TCP Sequence Number Difference: Enter a value in this field. This value represents the maximum sequence number difference allowed between subsequent TCP packets. If this number is exceeded, the packet is dropped. The acceptable range is 0 – 65535. A value of 0 (zero) disables this check.
•Enable default mapping to router: This is disabled by default. Toggling this option to Yes will allow the router to respond to traffic received on this interface, for example, ICMP Echo requests.