WAN and System Configuration 2-25

IP Profile Parameters

Address Translation Enabled:

No

IP Addressing...

Numbered

Stateful Inspection Enabled:

Yes

Stateful Inspection Options...

 

Local WAN IP Address:

0.0.0.0

Local WAN IP Mask:

0.0.0.0

Filter Set...

 

Remove Filter Set

 

RIP Profile Options...

Configure IP requirements for a remote network connection here.

Select Stateful Inspection Options and press Return. The Stateful Inspection Parameters screen appears.

Stateful Inspection Parameters

Max. TCP Sequence Number Difference:

0

Enable default mapping to router:

No

Deny Fragmented Packets:

No

Exposed Address List...

 

Enter max. allowed TCP sequence number difference (1 - 65535), 0 to disable.

Max. TCP Sequence Number Difference: Enter a value in this field. This value represents the maximum sequence number difference allowed between subsequent TCP packets. If this number is exceeded, the packet is dropped. The acceptable range is 0 – 65535. A value of 0 (zero) disables this check.

Enable default mapping to router: This is disabled by default. Toggling this option to Yes will allow the router to respond to traffic received on this interface, for example, ICMP Echo requests.