Page 270 of 332 Chapter 18 — Connecting the trunks

NT5K19 Analog TIE line trunk card terminations

Cross connect the NT5K19 analog TIE line trunk card as shown in Table 71.

Note: The speech pairs on the NT5K19 card are polarity insensitive. The E&M signalling pairs, however, are polarity sensitive. Make sure the ground side of the trunk is connected to the A leg of the NT5K19 circuit. Make sure the -50 volt side of the trunk is connected to the B leg.

Table 71

NT5K19 2W paging mode terminations

Pair

Pins

Pair color

Unit number

 

 

 

 

T0

27

W-O

 

R0

2

O-W

Unit 0

A

29

W-BR

 

PG

4

BR-W

 

 

 

 

 

T1

31

R-BL

 

R1

6

BL-R

Unit 1

A

33

R-G

 

PG

8

G-R

 

 

 

 

 

T2

35

R-S

 

R2

10

S-R

Unit 2

A

37

BK-O

 

PG

12

O-BK

 

 

 

 

 

T3

39

BK-BR

 

R3

14

BR-BK

Unit 3

A

41

Y-BL

 

PG

16

BL-Y

 

 

 

 

 

553-3021-209 Standard 3.00 April 2000

Page 270
Image 270