Nortel Networks Option 11C Mini manual Miscellaneous items for installation

Models: Option 11C Mini

1 334
Download 334 pages 10.31 Kb
Page 40
Image 40

Page 40 of 332 Chapter 2 — Identifying the Option 11C Mini equipment

Table 6

Option 11C Mini miscellaneous cables and wires (Continued)

 

Cable and wire

Purpose / description

 

 

 

 

 

 

#6 AWG (20 mm2) insulated

The #6 AWG (20 mm2) insulated

 

 

ground wire (Europe)

ground wire connects a chassis to a

 

 

 

building ground source.

 

 

 

 

 

 

#8 AWG (10 mm2) insulated

The #8 AWG (10 mm2) connects a

 

 

ground wire (Germany)

chassis to a building ground source.

 

 

 

 

 

 

Cross-connect wire

The cross-connect wire makes cross

 

 

 

connections at the cross-connect

 

 

 

terminal.

 

 

 

 

 

Note 1: This cable is available in different versions, depending on local EMC specifications.

Note 2: These cables are not supported under EMC specifications VL43.140P.

Miscellaneous items for installation

The following is a list of miscellaneous items that you can use as part of Option 11C Mini system installation. Quantities needed depend on the site and customer requirements:

QUA6 Power Failure Transfer Units (PFTU) to transfer lines during a power or system failure

NTBK80 grounding block

modems or Data Communication Equipment (DCE) for remote access to the system

on-site Data Terminating Equipment (DTE) or TTY terminal for accessing the system

connecting blocks for the cross-connect terminal

transformers and centralized power supplies for items such as digit displays on telephones

optional equipment such as music sources, RAN machines, paging equipment, and CDR devices

NTAK92 Off-Premise Protection Module for connecting up to four off-premise analog telephones